Basic Info.
Kind
Digital Oscilloscope
Application
Voltage Measurement, Magnetic Field Measurement, Pressure Measurement
Sampling Mode
Real-time Sampling
Trigger Modes
Conventional
Deeper Memory Depth
1Mpts
Waveform Capture Rate
30000 wfms/s
Built-in Signal Source
Without Built-in Signal Source
Product Description
Hantek Digital Oscilloscope DSO4084B 80MHz 4Channels 1GSa/s Real Time Hantek DSO4084 Over 32 types of auto measurement function
Feature:
2 Channel Digital Oscilloscope + Arbitrary/Function Waveform Generator + Synchronizing Signal + External Trigger;The Keys for osilloscope and waveform generator is seperated for convenient to operate it simultaneously;Large and clear display (7 inch 64K color LCD display, Resolution 800x480), more clear and realistic waveform; Oscilloscope: 1GSa/s Sample Rate, 200/100/70MHz Bandwidth, more than 20 kinds of auto measurement functions;Powerful Trigger Function: Edge, Video, Pulse, Slope, Over time, Alternative;Arbitrary/Function Waveform Generator: 25MHz, 12 bits resolution, 200MHz DDS, Arbitrary wave/square wave/sine wave/triangle wave/trapezoidal wave/pulse wave/DC is easy to simulate transducer.Support SD card, VGA function (optional);Integrated USB Host, Support USB disk storage, USB interface/SD card system update.
Model | DSO4202C | DSO4102C | DSO4072C |
Oscilloscope | | | |
Sample Rate | Sampling Rate Range: 1GSa/s |
Equivalent Sample Rate: 25GSa/s |
Acquisition Modes |
Normal | Normal data only |
Peak Detect | High-frequency and randon glith capture |
Average | Wavefom Average, selectable 4,8,16,32,64,128 |
Inputs | | | |
Inputs Coupling | AC, DC, GND |
Inpits Impendance | 1MΩ±2% 20pF±3pF |
Probe Attenuation | 1X, 10X |
Supported Probe Attenuation Factor | 1X, 10X, 100X, 1000X |
Maximum Input Voltage | CAT I and CAT II: 300VRMS (10×) |
CAT III: 150VRMS(1×); |
Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur. |
Horizontal | | | |
Sample Rate Range | 1GS/s |
Waveform Interpolation | (sin x)/x |
Record Length | 40K |
SEC/DIV Range | 2ns/div to 40s/div |
Sample Rate and | ±50ppm(at over any ≥1ms time interval) |
Delay Time Accuracy |
Position Range | 2ns/div to 8ns/div; (-8div x s/div) to 20ms; | 20ns/div to 80us/div; (-8div x s/div) to 40ms; |
200us/div to 40s/div; (-8div x s/div) to 400s |
Delta Time Measurement Accuracy (Full Bandwidth) | Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns); Sample interval = s/div ÷ 200 |
|
Vertical |
Vertical Resolution | 8-bit resolution, all channel sampled simultaneously |
Position Range | 2mV/div to 10V/div |
Bandwidth | 200MHz | 100MHz | 70MHz |
Rise Time at BNC( typical) | 1.8ns | 3.5ns | 5ns |
Offset Range | 2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±1V 500mV/div to 2V/div, ±40V; 5V/div to 10V/div, ±50V |
|
Math | +, -, *, /, FFT |
FFT | Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman; |
1024 sample point |
Bandwidth Limit | 20MHz |
Low Frequency Response (-3db) | ≤10Hz at BNC |
DC Gain Accuracy | ±3% for Normal or Average acquisition mode, 10V/div to 10mV/div; |
±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div |
DC Measurement Accuracy, Average Acquisition Mode | When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 10V/div |
Volts Measurement Repeatability, Average Acquisition Mode | Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions |
Trigger System |
Trigger Types | Edge, Video, Pulse, Slope, Over time, Alternative |
Trigger Source | CH1, CH2, EXT, EXT/5, AC Line |
Trigger Modes | Auto, Normal, Single | | |
Coupling Type | DC, AC, Noise Reject, HF Reject, LF Reject |
Function Pictures
FAQ
A: Payment Terms:
T/T, Western Union, Paypal, Bank Transfer
B: Shipment:
1. By EMS, DHL, FedEx, TNT, UPS or other express.
2. By your own forwarding agent.
3. Buyer can choose the desired shipping method when ordering.
C: After-sale service:
All products have been checked and packaged in good condition before dispatch.
D: Lead Time:
After the payment, general orders will be delivered from our factory within 3-5 working days.
Customers Service
Please contact us through email or phone, we will assist you in any way possible
China working hours 9:30-18:30 Monday-Friday online service to help buyers solving problem.
Welcome the friends from all over the world to visit us !
Address:
607, Block A, Electric &Technology Building, Middle Shennan Road, Shenzhen, China
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics
Management System Certification:
ISO 9000
Company Introduction:
Our company supplies different kinds of products. High quality and favorable price. We′re pleased to get your Inquiry and we will come back to as soon as possible. We stick to the principle of "quality first, service first, continuous improvement and innovation to meet the customers" for the management and "zero defect, zero complaints" as the quality objective. To perfect our service, we provide the products with good quality at the reasonable price.